Maxxicharge Home Assistant Integration: V2+ Locally via MQTT
At midday a solar system produces more power than the house needs; in the evening it is the other way round, and power comes from the grid even though you generated enough during the day. A home battery closes that gap. The Maxxicharge V2+ from Maxxisun is a plug-in storage system with its own inverter: solar modules can be connected to its battery blocks, like a balcony solar kit with storage. If you already have a solar system, you can also run it without modules of its own – it then charges through a wall socket with the surplus of your existing system. That is how we tested it. We show how to set it up, how the Maxxicharge Home Assistant integration works and how well it actually pushes grid import down to zero.
The MQTT interface of the control unit (CCU) is new. We followed it from the first firmware with MQTT (2.42.103) through to version 2.43.21, which Maxxisun now ships to customers, using a test build of the app. Without the interface, the battery and the zero-export control work just the same – only the Home Assistant integration is missing; how to check whether your CCU already has it is explained in step 3 of the MQTT setup. What the updates changed is listed under the limitations below.
Maxxisun provided the CCU and the battery block for this test. The article was not paid for, and Maxxisun did not see it before publication.
You can use the Maxxicharge in two ways:
• With its own solar modules: the modules are connected to the storage system; it charges from them and feeds power into the home grid through its inverter – a balcony solar kit or a small solar system with storage.
• As a pure AC battery (our test): without modules of its own, it charges through the wall socket with whatever surplus an existing solar system currently has and returns that energy to the home grid later. It is not connected to that solar system; it only “sees” its surplus at the grid connection.
To know when to charge and when to discharge, an additional measuring device – called “Smartmeter” in the app, meter for short here – continuously measures the power at the grid connection: if power flows into the grid, the battery charges; if power is drawn from the grid, it discharges exactly enough to cancel the import. This constant tracking is called zero-export control. It only works as well as the meter measures quickly and correctly.
Key takeaways
- The Maxxicharge consists of the control unit (CCU, with inverter) and one or more battery blocks, to which solar modules can also be connected. We used it without modules of its own as an AC battery next to our solar system.
- The CCU needs a meter at the grid connection to match charging and discharging to the house: an optical reading head, a Shelly (Pro) 3EM or a Shelly meter emulated in Home Assistant.
- Once MQTT is set up in Home Assistant and the broker is entered in the CCU, Home Assistant creates the device with its readings and settings automatically.
- Reading via MQTT works completely. The first firmware rejected changes to settings; since firmware 2.43, the CCU accepts them from Home Assistant.
- The output control keeps the grid connection within a few watts on average. After a load step, it took 5 to 18 seconds in our test until the grid connection was back within ±60 W of the new value.
- A full 3 kWh block covered our evening (around 420 W base load) until about 11 pm, not the whole night.
Our test setup
- Control unit with inverter: Maxxicharge CCU V2+
- Battery: one Maxxicharge M3.0 V2+ block with 3 kWh
- Solar system: Huawei SUN2000 with EMMA (Energy Management Assistant), 5.5 kWp
- Meter: a Shelly Pro 3EM emulated in Home Assistant (Huawei EMMA as a Shelly Pro 3EM)
- Smart home: Home Assistant OS 18.3 with Core 2026.9.4 and the “Mosquitto broker” app
- App: Maxxisun app 2.0.102 (beta from TestFlight, iOS) – menu names may differ in the regular app
- CCU firmware: 2.42.103 to 2.43.21 (as of 19 October 2026)
The box contains the CCU, the battery block, the cable between the two and a power cable with a Schuko plug (the German socket type). According to the product page, the CCU V2+ currently costs €599 (regularly €729) and outputs at most 800 W in its basic version. With the paid “ready2plugin” activation (€179 extra, more on that under “Assembly and commissioning”), up to 2,300 W are available in the home. One M3.0 V2+ battery block costs €749. Prices are from Maxxisun’s German shop as of 7 October 2026; converted roughly, that is about $675 / £510 for the CCU, $200 / £150 for ready2plugin and $845 / £635 for a battery block (exchange rates of 6 October 2026, for orientation only).
What you need
Besides the CCU and at least one battery block, you need:
- a suitable meter at the grid connection (next section)
- a wall socket and Wi-Fi or a LAN connection where the unit will stand. The CCU needs internet access for the initial setup; after that only for firmware updates and if you want to check the system via the manufacturer’s app while away from home
- the Maxxisun app for setup (iOS or Android)
- only for the Home Assistant integration: Home Assistant with the “Mosquitto broker” app and a CCU firmware with the MQTT interface. The battery and zero-export control also work without Home Assistant and with older firmware.
Is the size right?
What matters is how much power you use after sunset. Our house constantly draws around 420 W in the evening and at night (fridge, router, servers, standby devices). Of the 3 kWh in a block, 2.9 kWh are usable according to the CCU; converting to AC loses some of it, and around 2.6 kWh of a full charge reached the house. For us, that lasted from the end of solar production until about 11 pm; after that, power came from the grid again.
As a rule of thumb, divide the usable energy by your evening base load to get the number of hours one block lasts. To cover the whole night at a similar load, you need a second block. With an electric car or a heat pump, a large home battery is the better choice. How close you get to zero overall and whether it pays off is covered in part 3 of the series: Battery Storage for Solar with Home Assistant.
Which meter?
The CCU must know at all times whether power is currently flowing into the grid or coming out of it at the grid connection – otherwise it cannot tell whether to charge or discharge. This measurement comes from a separate meter that the CCU queries over your home network. It does not access the data of your solar inverter. This does not mean your utility meter itself but an additional measuring device; a reading head merely reads the utility meter. The app offers these devices:
| Meter | How it measures | For whom |
|---|---|---|
| Reading head (EcoTracker, Poweropti, IOmeter) | reads the utility meter’s display via infrared; attached magnetically, no wiring | anyone with a digital utility meter that has an infrared interface |
| Shelly 3EM, Shelly Pro 3EM | measures with current clamps directly on the cables in the meter cabinet | anyone who already has a Shelly in the cabinet or has an electrician install one |
| Shelly Pro 3EM emulated in Home Assistant | a program serves readings that Home Assistant already has in the format of a Shelly | anyone who already has the grid connection power in Home Assistant (see box below) |
Set up the meter before commissioning the CCU. For a reading head such as the Everhome EcoTracker*, your utility meter must output two things: import and export (a bidirectional meter, standard with solar systems) and the current power. Many German smart meters only show the current power after you enter a PIN that you request from the metering operator – often your grid operator. Request the PIN early; it sometimes takes a few days. How reading works is explained in our guide to reading a smart meter.
Maxxisun intends a dedicated meter for the control, such as a reading head. Instead, we provided the meter value from our existing Huawei system via Home Assistant: a small program serves the grid power of the Huawei EMMA in the format of a Shelly Pro 3EM, and the CCU takes it for a real Shelly. This is not a setup supported by Maxxisun. The guide is in the article Huawei EMMA as a Shelly Pro 3EM.
Assembly and commissioning
The Maxxicharge consists of two stacked parts: the battery block at the bottom and the CCU (Central Control Unit) on top. The CCU contains the inverter, which converts DC from the battery into AC for the home grid and the other way round when charging, and it controls how everything works together. On its back are the connection to the home grid, two backup power outputs (one of them a Schuko socket that stays live during a power outage – it is only live at all when backup mode (UPS) is switched on in the settings; it was off on our unit), LAN and the battery connections. According to the manufacturer, solar modules are connected to the battery blocks, up to 4,000 W per M3.0 block. In our test these inputs stayed free because the existing system supplies the power.
The CCU and battery block make a high-quality, well-thought-out impression: sturdy housings, a large aluminium heat sink, recessed grips for carrying and neatly labelled connections. Maxxisun is based in Saxony, Germany; according to the manufacturer, the batteries are developed and built in Germany. Maxxisun is not a newcomer, though: according to the company, it presented the first plug-and-play control for balcony solar batteries in Germany back in July 2023, measuring the consumption of the whole house and adjusting the output to match. The system was expandable from the start, and the Maxxicharge V2+ is its third generation.
The CCU simply plugs into a normal wall socket. For plug-in operation, Maxxicharge relies on ready2plugin. According to the manufacturer, this activated safety function monitors the load on the connected circuit and limits the power when necessary. With a suitable configuration, up to 2,300 watts can be used in the household while feed-in to the public grid is limited to 800 VA. Maxxisun refers to the German standard DIN VDE V 0100-551-1 and its own manufacturer’s declaration. According to the manufacturer, connection to a suitable existing Schuko socket without hard wiring is intended. Requirements include a compatible meter and compliance with the connection specifications. Whether additional electrical work is necessary depends on the existing installation; if in doubt, ask an electrician or your grid operator. These rules refer to Germany – outside Germany, check your local regulations for plug-in storage. Whether the extra cost is worth it depends on your consumption: if your house regularly draws more than 800 W in the evening, the CCU covers only part of it without ready2plugin, and the rest comes from the grid.
Commissioning was straightforward for us and done within a few minutes; the included manual is pleasingly detailed and informative. In Germany you must register the battery in any case: in the Marktstammdatenregister (the Federal Network Agency’s register) and with your grid operator; Maxxisun offers a service for this. In other countries, check which registration your grid operator requires.
About the location: a faint whine can be heard during operation. You will notice it in the same room, but not behind a closed door – a storage room or basement is better than a living room or bedroom. Outdoor operation is possible, but for the sake of its service life the unit should be well protected from weather and direct sunlight; follow the manufacturer’s instructions.
Step by step
- Connect the battery block and the CCU with the supplied cable, switch the battery block on and give it a number (ID). Which buttons to press is shown in Maxxisun’s manual.
- Plug the CCU into a normal wall socket with the power cable.
- Switch on the inverter and CCU switches (see the manual). If the inverter is off, the CCU neither charges nor discharges, and the app permanently shows 0 W output.
- In the Maxxisun app, choose “Add device”. Keep your phone close by: the app finds the CCU via Bluetooth.
- Connect the CCU to your home network via Wi-Fi or a network cable. Give it a fixed IP address in your router – you will reach its web interface at this address later, and Home Assistant will reliably find it again.
- Confirm the notes on solar voltage. They concern modules you may connect to the storage system.
In the CCU settings in the app, you also define down to which charge level the battery may discharge and up to which level it may charge (charge limits in percent), and the maximum power it outputs and draws. With a lower limit of 0 %, our CCU kept discharging until the block was practically empty; a higher limit keeps a reserve, for example for the backup power output. That outlet only carries voltage once you switch on backup mode (UPS) – in the app or, later, from Home Assistant; for us it took about 30 seconds after switching it on. How the outlet behaves under load is covered in part 3 of the series in the “Backup power” section.
Adding the meter in the app
Under “Smartmeter”, the app searches for meters in your home network. If your meter appears in the list, select it. If the app does not find it – as with our emulated Shelly – the link for manual entry (“manuelle Eingabe” in the German app) takes you further: there you choose the meter type and enter its IP address in your home network (for the Poweropti, also its key).
Important for the emulated Shelly: the CCU queries a Shelly Pro 3EM every second on port 80, the usual port for websites. You cannot enter a different port in the app, so the program that emulates the Shelly has to answer on port 80. On Home Assistant OS installed fresh from 2026.8 onwards, though, Home Assistant takes port 80 itself. If you open Home Assistant without :8123, move it back to port 8123 first.
Shortly after saving, the app’s home screen shows what is happening: how much power is coming from the grid (grid import), how much the CCU is outputting and how full the battery is. If everything is regulating correctly, grid import stays close to zero.
Integrating with Home Assistant via MQTT
From here on, it is about the Home Assistant integration. It runs via MQTT, a lightweight protocol that devices use to send readings. The devices do not send their values directly to Home Assistant but to an intermediary, the broker; Home Assistant picks them up there. The CCU also announces to the broker which readings and settings it has, and Home Assistant creates sensors for them automatically (MQTT discovery). You do not need an additional integration or a cloud for this. The basics are covered in our guide to MQTT with Mosquitto.
1. Install the broker in Home Assistant
If you already have an MQTT broker, skip this step. Otherwise:
- In Home Assistant, open Settings → Apps → App store, install “Mosquitto broker” and start it.
- Under Settings → Devices & services, the discovered “MQTT” integration then appears. Confirm with Add or Configure.
2. Create an account for the CCU
The Mosquitto broker in Home Assistant lets in all Home Assistant users. So that the password of your own account is not stored in the CCU, create a separate user for it: Settings → People, tab Users (the tab only appears when advanced mode is enabled in your profile). Name it something like “maxxicharge”, do not give it administrator rights and allow login only from the local network.
3. Enter the broker in the CCU
Open the CCU’s web interface in a browser: http://CCU-IP-ADDRESS/integrations/mqtt (the fixed IP address from the setup, see “Step by step”; you can also find it in the app under CCU settings → Connection). Alternatively, you can set up the connection in the app under CCU settings → Smart Home Integration, as long as your phone is on the same network; we used the web interface. If the page does not open or MQTT cannot be saved there, your CCU does not have the interface yet – then all you can do is wait for the firmware update (the interface arrived with version 2.42.103; the version is shown on the same page). Otherwise:
- switch on the MQTT connection
- enter Home Assistant’s IP address as the broker address and leave port 1883 (the standard MQTT port)
- switch on authentication and enter the username and password of the new user
- click save
4. Check what arrives in Home Assistant
After a few seconds, the device “CCU2” appears under Settings → Devices & services → MQTT. Its values update about every second. If the device does not appear or all values show “Unavailable”, save the MQTT settings in the CCU’s web interface once more – for us this restored the connection every time. With the first firmware this was necessary every few hours; since version 2.43.19 it has not been.
This is what the CCU provides, sorted by area:
| Area | What you see |
|---|---|
| Battery | state of charge in percent, current charging or discharging power, stored energy, usable capacity (2,919 Wh in our case), voltage |
| CCU | power output to the house, temperature, operating mode, currently effective limits for charging and output |
| Meter | power at the grid connection, import and export today and in total |
| Energy | total energy charged and discharged |
| Diagnostics | error messages from battery and inverter, meter failure, firmware version |
| Settings | charging strategy, maximum charging and output power, output on meter failure, charge limits, backup power mode (UPS) |
Two things help when reading the values. First, the signs: positive values mean the battery is discharging, the CCU is outputting power to the house or power is coming from the grid; negative values mean the opposite direction. Second, the battery’s energy counters are estimates that the CCU saves about every five minutes – fine for charts and automations, not for precise accounting.
What you can control via MQTT – and what not
The CCU also exposes settings in Home Assistant: the charge limits, the maximum charging and output power, the output when the meter fails, the charging strategy and the backup power mode. With these, Home Assistant could, for example, keep a reserve for the backup outlet ahead of dark days. With a flat electricity price you rarely need more: a stored kilowatt-hour is worth the same at noon as in the evening, and the CCU handles zero-export control on its own.
Two things are fundamentally not possible via MQTT: you cannot give the CCU a fixed setpoint such as “output 300 W now”, and Home Assistant cannot supply it with the power at the grid connection – output control always runs via its meter.
With the first firmware (2.42.103), the CCU rejected every change made via MQTT (“rejected”). Since firmware 2.43 it accepts settings from Home Assistant: in our test on 19 October (version 2.43.21), a changed output limit showed up as the effective value in the CCU within a second. Two things are worth knowing: according to the documentation, the answer “applied” only means the setting was saved – whether the power actually changes is visible in the readings. And if the CCU rejects a value, Home Assistant shows no error; the slider simply jumps back to the old value. So run changes through a small script that sets the value, waits briefly and checks what the CCU reports back; an example, along with an automation for a backup-outlet reserve, is in part 3 of the series.
How well does the battery regulate?
Whether zero-export control works shows at the grid connection: if it stays at zero, no power comes from the grid and none goes out. We measured the power at the grid connection with our Huawei EMMA, which delivers a value to Home Assistant every two seconds, plus the CCU’s own readings. Our CCU has ready2plugin and may therefore output more than 800 W; charging and output were limited to 1,000 W in the app during the measurements.
| Situation | Power at the grid connection |
|---|---|
| Evening, steady consumption below 1,000 W | 0 to +4 W averaged over 5 minutes; individual readings fluctuate by ±50 to 100 W |
| Daytime, battery charging from solar surplus below 1,000 W | −8 to −4 W averaged over 5 minutes |
| Consumption or surplus above 1,000 W | the part above 1,000 W comes from or goes to the grid – that is the configured limit, not a control error |
It gets interesting when consumption changes suddenly. To test this, we switched on a 720 W appliance three times for two minutes. At that moment the 720 W come from the grid until the battery catches up. When switching off it is the other way round: the battery briefly outputs too much and the surplus flows into the grid. Because output was limited to 1,000 W, around 200 W came from the grid while the load was running – grid power settles at this new value, not at zero.
- Our meter from Home Assistant reported the change to the CCU after 1.4 to 3.7 seconds.
- The CCU started adjusting its output after about 4 to 12 seconds.
- After 5 to 18 seconds, the grid connection was back within ±60 W of the new value.
- In total, about 1 Wh too much or too little flowed per switching event – less than an LED bulb uses in a quarter of an hour.
In one of the six switching events (in the chart shortly after 18:51), the CCU output too little for about 20 seconds after switching off, so up to 1,000 W came from the grid even though its meter delivered the correct value. Three runs are a sample, not statistics. Most of the delay is caused by the CCU itself, not by our meter; still, a real Shelly in the meter cabinet would be somewhat faster than the detour via Home Assistant and would save a few more watt-hours of grid import over the day.
Limitations and open points
As of 19 October 2026, firmware 2.43.21. Issues that the updates since the first MQTT firmware have fixed stay listed here, with dates.
- MQTT connection (fixed): with firmware 2.42.103, the connection to Home Assistant dropped after a few hours and did not come back by itself; saving again helped (see step 4 of the MQTT setup). Since version 2.43.19 of 15 October, we have only seen dropouts of a few seconds when the CCU restarts. Zero-export control keeps running regardless. Monitoring on the Home Assistant side still makes sense, especially if you change values via automations.
- Local interface: independently of MQTT, the CCU serves its values as JSON on your home network:
http://<CCU-IP>/api/livereturns charge level, power and remaining energy,/api/historyan internal history (for example?level=hours&from=…&to=…with Unix timestamps). This could fill gaps during MQTT dropouts, for example with a REST sensor in Home Assistant. We found no documentation for it, so the interface may change with new firmware. It also runs without authentication. - Control via MQTT (fixed): firmware 2.42.103 rejected settings; since 2.43 they are accepted (see above).
- Meter message (fixed): up to firmware 2.43.11, the CCU occasionally reported for about a second that its meter was not responding, although our emulated meter had answered every request within 1 to 2 milliseconds. Since 2.43.19 the message has not appeared again.
- App: there is still no field for the meter port; the data export lacked a column for the charged energy.
- Security: MQTT runs without encryption, and the CCU’s web interface for the MQTT configuration has no login. Anyone on your home network can open it. Only run the CCU on a network you trust and, if necessary, separate it from the rest of your home network.
- Savings in the app: the app multiplies the energy output by an electricity price you set yourself. It does not account for the feed-in tariff you forgo for the stored energy (balcony solar kits usually get none, our system does), nor for the losses. Discharging alone (battery → house) loses 7 to 20 % depending on output power – most at around 120 W, least from about 500 W up; over a full cycle – charging, storing, discharging – 74 % of the energy taken in came back to the house on average (70 to 79 % over four measured cycles, CCU counters; the best value with firmware 2.43.19).
We will update this article with what changes in future versions.
Conclusion
The Maxxicharge V2+ can be integrated with Home Assistant locally: enter the broker, and all readings arrive without a cloud; since firmware 2.43, settings can be changed from there as well. Zero-export control with our virtual meter from Home Assistant ran surprisingly stable and kept grid import at a few watts on average.
We were impressed by the high build quality and by our contact with Maxxisun: questions were answered quickly, and in the two weeks of the test five firmware updates arrived that took care of the dropping MQTT connection, the meter messages and the rejected settings. A few small things remain: no port field for the meter in the app, a web interface and MQTT without login or encryption, and battery energy counters that are estimates. Part 3 of the series puts it all in context: which battery fits which household, what it delivers over the year, the rules, the Energy dashboard and automations. Have fun building!
Frequently asked questions
Yes. The CCU connects to your own broker via MQTT, and Home Assistant creates the sensors automatically through the MQTT integration. No additional HACS integration is needed. The interface arrived with firmware 2.42.103; we tested up to version 2.43.21.
Yes, since firmware 2.43: charge limits, maximum charging and output power, charging strategy and backup power mode. The first firmware with MQTT (2.42.103) still rejected changes. You cannot set a fixed power value – the CCU always regulates its output via its meter.
Yes. The CCU regulates to its meter’s value; Home Assistant cannot supply it with the grid connection power via MQTT. Options are an optical reading head, a Shelly (Pro) 3EM or a Shelly Pro 3EM emulated in Home Assistant.
Yes. You only need Home Assistant if you want to see and use the values there. The battery and zero-export control run with the meter and the app alone.
In our measurements, the CCU started adjusting 4 to 12 seconds after a load change, and after 5 to 18 seconds the grid connection was back within ±60 W of the new value. With steady consumption it stayed at a few watts on average.
Divide the usable energy by your consumption: about 2.6 kWh of a full charge reached our house, and at around 420 W base load that lasted from the end of solar production until about 11 pm.